circuitnet
Sponsor
Advanced Interconnections Corp.
Plan Ahead for BGA Device Upgrades
BGA Socket Adapter Systems convert surface mount device packages to through-hole (pinned) assemblies, making it easy to plug and unplug SMT devices in the field or the test lab.
Advanced Interconnections Corp.
Rentals and Rent to Purchase x-ray Systems
Sponsor
ECD
Maybe it's the thermocouple connection
If your thermal profiling readings seem inconsistent, the culprit could be your thermocouple attachment method. A recently conducted study revealed some interesting findings.
ECD

Reducing Dust Deposition on Electronic Equipment



Reducing Dust Deposition on Electronic Equipment
This work focuses on one aspect of reducing dust accumulation on electronic equipment, specifically by optimizing the cooling air flow.

DOWNLOAD
Authored By:
Chen Xu
Jason Stafford
Nokia Imperial College London

Summary

Environmental dust accumulation on electronic equipment can impact the performance and reliability of the equipment in various ways. This includes mechanical effects (such as obstructions of cooling air, moving parts and optical interference), chemical effects (such as corrosion and metallic dendrite growth) and electrical effects (such as impedance reduction, short and open circuits). Minimization of dust deposition on electronic equipment is necessary and beneficial to product performance and long-term reliability. This work focuses on one aspect of reducing dust accumulation on electronic equipment, specifically by optimizing the cooling air flow.

Conclusions

This work presents a detailed analysis on dust deposition mechanisms in air cooled electronic equipment using particle image velocimetry performed in situ on a cellular base station. Localized preferential dust deposition is driven by high velocity air flowing at an oblique angle at the exit of rotating axial fans. This oblique angle is a characteristic of all rotating axial fans, due to centrifugal forces in the exiting jet. This produces locally increased deposition velocities that is more than two orders of magnitude higher in zones where dust deposition was observed in the field. It was demonstrated that the addition of traditional filters on the fan inlet side may worsen the situation by enhancing the deposition mechanism through changes to the impingement angle. Finally, a method is proposed which uses aerodynamic guide vanes to control the flow locally, reducing the deposition mechanism while having negligible effect on the bulk fan performance. This work also highlighted the importance of maintaining low concentration of PM2.5 dust (most detrimental dust to electronic equipment) at the data center and the most practical and cost-effective way for removing PM2.5 is at the room level.

Initially Published in the SMTA Proceedings
Submit A Comment
Comments are reviewed prior to posting. You must include your full name to have your comments posted. We will not post your email address.

Your Name


Your Company
Your E-mail


Your Country
Your Comments



Free Newsletter Subscription
Circuitnet is built for professionals who bear the responsibility of looking ahead, imagining the future, and preparing for it.

Insert Your Email Address

Sponsor
Uyemura
RAIG Minimizes Corrosion, Allows Higher Gold on ENEPIG
Paper describes a mixed reaction RAIG electrolyte that minimizes galvanic corrosion and allows higher ENEPIG gold thicknesses, enabling robust designs and world-class quality on target with minimal variation.
Uyemura
Affordable Profiling