circuitnet
Sponsor
Advanced Interconnections Corp.
Plan Ahead for BGA Device Upgrades
BGA Socket Adapter Systems convert surface mount device packages to through-hole (pinned) assemblies, making it easy to plug and unplug SMT devices in the field or the test lab.
Advanced Interconnections Corp.
Rentals and Rent to Purchase x-ray Systems
Sponsor
ECD
Maybe it's the thermocouple connection
If your thermal profiling readings seem inconsistent, the culprit could be your thermocouple attachment method. A recently conducted study revealed some interesting findings.
ECD

Recent Technology Advances for X-ray Inspection



Recent Technology Advances for X-ray Inspection
This paper reviews x-ray system types and what they provide for resolution, magnification, power, pixel size and the effects of radiation damage.

DOWNLOAD
Authored By:
David Bernard, Ph.D., Keith Bryant
Nordson DAGE, Aylesbury, Buckinghamshire, U.K.

Summary

Taking x-ray images goes back over 100 years. Since then, there have been numerous advances in terms of x-ray tube and x-ray detector technology and these have been increasingly applied into helping with the manufacturing of electronic components and assemblies, as well as in their failure analysis. Most recently, this has been rapidly driven by the continued reduction in board, device and feature size and the movement to using newer, lower density materials within the structures, such as copper wire replacing gold wire as the interconnection material of choice within components.

In order to meet these challenges and those in the future, there have been a number of recent key improvements to the vital components within x-ray systems. In particular, there is a new x-ray tube type that permits high magnification inspection at improved resolution, yet retains high tube power under these conditions, allowing good x-ray flux for inspection of the smallest features. There is also the availability of new and improved x-ray detectors (both image intensifiers and CMOS Flat Panels) that are now specifically designed for electronics applications, rather than hand-me-downs from the needs of the medical market, which are able to take best advantage of these tube developments.

The choice of available technologies, however, means selecting the tube / detector combination which is optimum for a particular electronics inspection application is no longer so clear cut. For example, one configuration may provide certain benefits that are applicable for one area of electronics inspection, whilst being less valid for others. This paper will review the various x-ray tube and detector types that are available and explain the implications of these choices for electronics inspection in terms of what they provide for inspection regarding image resolution, magnification, tube power, detector pixel size and the effects of detector radiation damage, amongst others. It will also suggest optimum configurations for the main electronics inspection tasks required today.

Conclusions

This paper has discussed the various x-ray tube and detector technologies that are available today for the x-ray inspection needs of electronics. It has shown their relative advantages and disadvantages and suggests some system configurations to provide the best inspection for particular applications.

Initially Published in the SMTA Proceedings
Submit A Comment
Comments are reviewed prior to posting. You must include your full name to have your comments posted. We will not post your email address.

Your Name


Your Company
Your E-mail


Your Country
Your Comments



Free Newsletter Subscription
Circuitnet is built for professionals who bear the responsibility of looking ahead, imagining the future, and preparing for it.

Insert Your Email Address

Sponsor
Uyemura
RAIG Minimizes Corrosion, Allows Higher Gold on ENEPIG
Paper describes a mixed reaction RAIG electrolyte that minimizes galvanic corrosion and allows higher ENEPIG gold thicknesses, enabling robust designs and world-class quality on target with minimal variation.
Uyemura
Affordable Profiling